Facility Control

 View Only
  • 1.  Loading and Saving Sets via Dashboard control vs. using the switch panel buttons. Is it possible?

    Posted 12-02-2016 17:36
    We have a Carbonite running 12.0.1.14515 and are running Dashboard 8.0.1. I looked and looked, but I could not find a way to load or save switcher sets via Dashboard. Is this not possible via the standard interface presented from the switcher through the software? I know we can load Set0 and 2 and so on via the Carbonite panel, but I was hoping there was a way to do it within Dashboard. Maybe I can program a command button to do this?
    Any help on this would be appreciated.
    Thanks!
    Grant


  • 2.  RE: Loading and Saving Sets via Dashboard control vs. using the switch panel buttons. Is it possible?

    Posted 12-02-2016 18:12
    Hi Grant,

    This is Jake from Ross Video Tech Support.
    I can confirm for you that this works, I've built a panel this morning to test!

    I am going to shoot you an email with some info, keep an eye out!

    Jake
    #DashBoard


  • 3.  RE: Loading and Saving Sets via Dashboard control vs. using the switch panel buttons. Is it possible?

    Posted 12-27-2016 11:26
    Grant, you can use the 'LOADSET setname' to load sets using a button in Dashboard. However I found that this doesn't load things like the busmap since thats stored in the mixers panel, not in the mainframe. :-)