Production Switchers

 View Only
  • 1.  Enabling MiniMEs in Version 8

    Posted 02-06-2014 23:42
    I've just upgraded to version 8 and I'm looking to enable MiniMes. I am unable to find where to do this either in Dashboard or from the panel. Can someone assist?

    Cheers


  • 2.  RE: Enabling MiniMEs in Version 8

    Posted 02-07-2014 06:32
    You can set them up in the menus. From page 34 of the setup manual:

    [QUOTE]

    DVE/FSFC Resources (Carbonite Frame Only)

    The Carbonite frame can support a limited number of DVE channels, FSFCs, and MiniMETM outputs. The switcher must be rebooted to switch between the two resource modes.

    To Switch Between DVE/FSFC Resource Modes



    [LIST=1]
  • Press MENU>SYSTEM>NEXT>NEXT>

  • NEXT > NEXT.
  • Use the D/F/M knob to select the reesource mode.

    • 8/0/4 "” provides 8 channels of DVE, 0 FSFC resources, and 4 MiniMETM resources
    • 4/6/0 "” provides 4 channels of DVE, 6 FSFC resources, and 0 MiniMETM resources

  • Press D/F/M > Reboot to apply the changed.

  • The switcher reboots to apply the changes to the resources.





    #Carbonite


  • 3.  RE: Enabling MiniMEs in Version 8

    Posted 02-07-2014 22:47
    Thank you James.

    #Carbonite