  • 1.  Image Video Tally

    Posted 06-27-2013 23:20
    Has anybody been successful in getting a Carbonite to talk to a TSI-3000?

    I think we have the serial cable wired correctly, the TSI only complains about baud not correct, and I have tried them all. But I still can not determine communications. This is in a brand new system with 1 Carbonite, 6 CCUs and 3 MVPs. I know an Image Video system is overkill but it is what they want to use.

    Also, we don't see it in Dashboard. But that is another problem...


  • 2.  RE: Image Video Tally

    Posted 07-03-2013 17:29
    Hi John,

    The TSI system may or may not contain the software implementation of the TSL UMD input code. The Image Video Guys sent us a unit for testing so that we could test it. We are sending the data over IP by the way not using the serial port. You may need to get a software update to support this feature.

    As for showing up in DashBoard -- the switchers don't use the SLP implementation and auto populate. In your basic Tree View you will need to press the + button to manually add a connection. Select openGear - then TCP/IP openGear Frame. Enter the IP address of your Carbonite. Change the Name to what you would like it to be seen as (i.e. Studio 1). Then Press Finish -- don't bother detecting settings this will not do anything.

    Les

    #Carbonite