Production Switchers

 View Only
  • 1.  Can On-Air Red Tally be assign only in ME4 PGM bus

    Posted 10-11-2017 09:57
    Dear Sir,

    Have work out with Acuity switcher and enjoy the Latest function.

    But can the switcher have only one bus have the Red Tally while it is put On-Air?

    All the ME1 PGM, ME2 PGM & ME4 PGM(set as Output PGM) buses have the Red Tally color, it make a little bit confused of the final PGM output.

    Hope can have the help form colleagues.

    Thanks frm Jackie


  • 2.  RE: Can On-Air Red Tally be assign only in ME4 PGM bus

    Posted 10-11-2017 21:44
    In the Output Menu you can turn on ON Air Status to Always for any ME you like.
    #Acuity


  • 3.  RE: Can On-Air Red Tally be assign only in ME4 PGM bus

    Posted 10-12-2017 05:02
    Dear Les,

    Thanks for the reply, it really work.

    regards from jackie
    #Acuity


  • 4.  RE: Can On-Air Red Tally be assign only in ME4 PGM bus

    Posted 10-12-2017 11:51
    Glad to hear that this solved your application.
    #Acuity