Production Switchers

 View Only
  • 1.  MLE Stills

    Posted 10-23-2013 18:54
    So we just got the MLE Still Stores which are great but...when I use a custom control that has nothing to do with them they are blown out and cleared. So I tried adapting a custom control and including calling up the stills I needed they still got blown out?? I guess I can add a pause...but that still makes me ponder why it would blow them out anyway


  • 2.  RE: MLE Stills

    Posted 10-24-2013 00:58
    this seems weird Chris.

    What version are you on? Are you recalling any memories in the Custom controls?

    Les

    #Vision


  • 3.  RE: MLE Stills

    Posted 10-24-2013 01:31
    Actually Les that is what I discovered after I dove deep into the CC..it was recalling a older memory on the MLE that of course was built before we had the MLE still store so now it makes since...sorry for the Duh moment... :)