  • 1.  Custom Control of UX via RossTalk

    Posted 04-24-2017 21:43
    I can not seem to get UX to receive commands from a CC I build in Carbonite Dashboard. I would normally expect to add UX as a device. I can add an Rosstalk Xpression sub-type device using the UX computer's IP, but I'm not sure that sub-type is correct, nor do I see a specific UX sub-type. When building an Event on UX I can trigger the event with a RossTalk GPI and "Global RossTalk Server Port" and instructions seem to indicate the proper syntax is the "IP:Port", but field will not take any IP address of the Carbonite. Any suggestions on what I need to do to get UX added as a device? Am I thinking about this completely wrong? I don't see any way to have Dashboard talk to UX.


  • 2.  RE: Custom Control of UX via RossTalk

    Posted 04-26-2017 00:09
    Hi Michael,

    I just use the xpression sub type. That works for me. Just make sure that Dashboard is listening on a different port to XPression if they're residing on the same computer.

    James.
    #Carbonite