  • 1.  VER-11

    Posted 09-17-2015 14:47
    I have been going over ver-11 many nice changes. I like the fact that you now can see what memories are being used. The problem is I do not see any way like in custom control to delete a memory so you can see it is empty and reuse it. Also is there any way to name the memories like custom controls?

    I found in custom controls under create/edit event: SWITCHER INSTALLATION, ME, ME CLEAN FEED, there is only one selection. KEYER-1. How do you select other keyers?


  • 2.  RE: VER-11

    Posted 03-19-2021 15:46

    There is only a selectable clean feed... This is not a Programable Clean feed like in Acuity.  You can not have a selection of Keyers you can only select to pull from it before a keyer and in order....