Production Switchers

 View Only
  • 1.  Rosstalk AUX bus Bug?

    Posted 03-26-2015 20:11
    Hello,

    I was reading another thread about a Rosstalk bug regarding AUX bus.

    We are trying to change AUX bus 2:1 and AUX 2:2 to XPT 12

    XPT AUX:9:IN:12

    XPT AUX:10:IN:12

    Those do not fire. Is this the correct text?

    I then read about a bug related to this. Would this bug be affecting our commands? If so, is there a workaround? We are using version 16.1f.

    Thanks in advance.

    Mike


  • 2.  RE: Rosstalk AUX bus Bug?

    Posted 03-26-2015 20:26
    Just checking -- you do have RossTalk IN setup as a device in the comm Setup? These are not enabled by default.

    Les

    #Vision


  • 3.  RE: Rosstalk AUX bus Bug?

    Posted 03-27-2015 13:27
    I will double check that with our Engs. In the meantime I can confirm we were able to get this to work with the PGM and PST bus on our MLE, we just can't get it to fire on the AUX bus.

    Thanks for your help Les.

    #Vision


  • 4.  RE: Rosstalk AUX bus Bug?

    Posted 03-27-2015 13:40
    We tested it here against the version you listed and it does work.

    The previous bug was just that only Aux 1:1 could not be controlled. All others were fine.

    Les

    #Vision