  • 1.  HD MultiView

    Posted 09-10-2012 22:57
    On our multiview, the graphics are hard to read. We are in standard def mode, if we change output of multiview to HD, to we have to change the cabling to outs 7 and 8?

    B


  • 2.  RE: HD MultiView

    Posted 09-13-2012 14:16
    Yes -- When the MultiViewer is put into and HD mode it requires special clocking and we have to lock it to a "pair" of outputs since we are now driving HD while in an SD mode. We had to chose where we wanted it and it was decided on outputs 7 and 8.