Production Switchers

 View Only
  • 1.  Carbonite tally with Harris Router Multiviewer

    Posted 10-14-2014 07:21
    Hi

    we have connected Ethernet connection of Carbonite Switcher Version 9.1 with Harris Router Inbuilt Multiviewer for tally purpose working on TSL 3.1 protocol. it is Connected but tally is working with Preset BUS not with PGM Bus.


  • 2.  RE: Carbonite tally with Harris Router Multiviewer

    Posted 10-14-2014 13:47
    Hi Atul,

    Sounds like the Harris MV needs to have some settings adjusted to define which Tally is the PGM Tally and not the PST Tally

    Les

    #Carbonite


  • 3.  RE: Carbonite tally with Harris Router Multiviewer

    Posted 10-15-2014 03:11
    Hi Les,

    there is no such type of settings in Harris MV.

    Atul Garg

    #Carbonite


  • 4.  RE: Carbonite tally with Harris Router Multiviewer

    Posted 10-15-2014 14:10
    Atul,

    We are just streaming out the data. Works with TSL, Image Video, Apantac and Evertz systems. I have not configured a Harris MV personally but I would have to expect that you can "Map" the tally info.

    Les

    #Carbonite


  • 5.  RE: Carbonite tally with Harris Router Multiviewer

    Posted 10-16-2014 14:48
    Les,

    Can you provide Some Document of Carbonite Version-9, for some Tally TSL protocol related,

    Regards

    Atul Garg

    #Carbonite


  • 6.  RE: Carbonite tally with Harris Router Multiviewer

    Posted 10-16-2014 14:53
    Hi Atul,

    Here is the link to the PDF form the Interfaces section of the Carbonite website.

    http://www.rossvideo.com/pdf/cutsheets/carbonite-interface/UMD_TSL(4802DR-613).pdf

    Les

    #Carbonite


  • 7.  RE: Carbonite tally with Harris Router Multiviewer

    Posted 10-16-2014 15:15
    Hi Les,

    Not getting two Points

    1. "The TSL UMD protocol v3.1 with Carbonite supports 16 characters with two tally outputs. Tally 1 is preview and Tally 2 is program. Tallies 3 and 4 are always off"

    2. Slot Number Selection, what is that Slot Number.

    Atul Garg

    #Carbonite


  • 8.  RE: Carbonite tally with Harris Router Multiviewer

    Posted 10-16-2014 16:59
    Slot number is when you are setting up the device under the devices menu. These are just device IDs for the Carbonite system. When you add the device you can chose from the available Slots (i.e. ones left available that don't yet have a device assigned to them).

    Les

    #Carbonite


  • 9.  RE: Carbonite tally with Harris Router Multiviewer

    Posted 10-16-2014 17:08
    Thanks Les

    What About 16 character with two tally output.

    Atul Garg

    #Carbonite


  • 10.  RE: Carbonite tally with Harris Router Multiviewer

    Posted 10-16-2014 20:17
    The system will send out "up to 16 characters for the names" as that is what TSL 3.1 protocol supports.

    There are 4 Tally events per source -- we only use 2 of them. We have it hard mapped as Tally 1 is PV and Tally 2 is PGM.

    Les

    #Carbonite