Production Switchers

 View Only
  • 1.  Custom Control Media Wipe End reset

    Posted 01-17-2020 19:37

    Tried everything we could think of before posting...

    We've got a custom control media wipe for replays - plays the wipe, transitions to the replay source, adds in the replay bug, then waits to reverse. This all works. The problem is that we can't figure out how to program the control to change back to dissolve when it's done. TDs are having to remember to manually change it.

    Tried using dashboard, tried recording. Stumped.

    Thanks!



  • 2.  RE: Custom Control Media Wipe End reset

    Posted 01-17-2020 20:55

    Hello. How much of a pause was entered after the Media Wipe Auto Trans command? Perhaps the length of the pause isn't sufficient to "finish" the MediaWipe before you're sending the command to change the Transition Type back to Dissolve. 


    #Carbonite


  • 3.  RE: Custom Control Media Wipe End reset

    Posted 01-19-2020 16:50

    That did it!
    Thanks so much!


    #Carbonite