Production Switchers

 View Only
  • 1.  Green tally from ME1-Pgm Bus

    Posted 02-08-2021 19:56

    We have Carbonite Ultra with Carbonite Black 2 Panel. Is there an option to split Green tally only from ME1 PGM Bus and red tally from P/P PGM Bus? 

    We have TSL umd device already set. 

    Thanks

    Stefan



  • 2.  RE: Green tally from ME1-Pgm Bus

    Posted 02-08-2021 20:30

    No Green tally is driven from relation to Preview and Red Tally is driven related to PGM.

    External controllers like TSL Tallyman can use the Bus messages in the system to create their own tally control.


    #Carbonite


  • 3.  RE: Green tally from ME1-Pgm Bus

    Posted 03-04-2021 00:39

    As a similar request, I'd love to see something like AUX outputs on left R/G tally and ME outputs on right R/G tally. It would be easier to distinguish in an external TSL tally system.


    #Carbonite


  • 4.  RE: Green tally from ME1-Pgm Bus

    Posted 03-04-2021 00:54

    Hi Gerry,

    We have "extended" the TSL v3.1 that we have in Carbonite.  TSL has a profile for it and is able to do "bus messaging" by looking at sources and Aux outs...

    So you can create Tally controls based on what those Aux outs are doing.  I would recommend talking to Daniel Bailey at TSL about what all they can do with this information...  Essentially we did this years ago specifically with them so that they could have more Data control and emulate similar things they would do with Contribution Protocol...


    #Carbonite