  • 1.  PGM tally on ME4 PGM mix

    Posted 12-27-2020 12:10

    I have change the MultiPanel Configuration from ME3 with Pgm Mix on ME3 Virtual Program to ME4 with PGM mix on ME4 Virtual Program ME.

    The PGM/PVW change to ME4, but the tally is still on ME3 and not ME4/PGM.

    Where can I change this? 



  • 2.  RE: PGM tally on ME4 PGM mix

    Posted 12-27-2020 17:17

    Where is the Tally coming from is it on the switcher connections or is this Tally in an external MV/Tally control system?


    #Acuity


  • 3.  RE: PGM tally on ME4 PGM mix

    Posted 12-27-2020 17:26

    Its coming from the switcher to an external MV/tally control system


    #Acuity


  • 4.  RE: PGM tally on ME4 PGM mix

    Posted 12-27-2020 17:51

    Check which Tally Protocol you are using.  If it is the Contribution Protocol then there are extra options to change which ME is the PGM ME... Also then make sure the other Slots are assigned correctly as well.... ie ME 1-4 with 4 Being the PGM ME.

    Setup guide is found here:

     

    http://help.rossvideo.com/acuity-device/Topics/Devices/Serial-Tally/GVG.html#topic.gvg

     

    Les


    #Acuity


  • 5.  RE: PGM tally on ME4 PGM mix

    Posted 12-27-2020 19:11

    Thanks! It was the Slot PGM who was wrong.

    I also have an issue with tally on key 5-8 on ME1-3. When they are on PGM they dont have tally, but key 1-4 have it. If you have a trick for this I would love to hear it!


    #Acuity


  • 6.  RE: PGM tally on ME4 PGM mix

    Posted 12-27-2020 20:16

    There is no trick for that :( ...

    The Contribution Protocol is the Legacy GVG Kayplso Protocol and only supports 4 Keyers and 4 MEs...Also IO of up to inputs 92....

    For full tally interface of everything you would need to change over the protocol to the TSL UMD v5.0 Protocol that Acuity Supports and also reconfigure the Tally Controller accordingly.

    Les


    #Acuity