Posted By Robert Pralle 05-24-2018 13:58
Found In Egroup: Facility Control
\ view thread
I am having two problems with DashBoard. First problem I am running dashboard on three computers Ver 8.3.1. The grid files I am running are located on our server. The reason is if I make a change to any one of the files the other computers will see the change when they re-load the file. This ...
Posted By Robert Pralle 12-13-2017 15:44
Found In Egroup: Facility Control
\ view thread
I have come up with a little problem. I moved my DashBoard to another path and found all my panel links were gone. Is there a way to have the links set for a relative path rather than an absolute path? All my panels are in a folder called Panels with sub folders it would be great if the panel link would ...
Posted By Robert Pralle 11-01-2017 19:27
Found In Egroup: Facility Control
\ view thread
I tried to sen a command to the 2nd computer with no success. Here is what I made in Visual Logic /*! block id=1006 !*/ rosstalk.sendMessage(params.getValue('CG_172.16.0. 113', 0), params.getValue('CG_172.16.0.113', 0), "GPI " + 1); /*!! block id="1006" type="CG_xpression_gpi" x="496" y="409" ...
Posted By Robert Pralle 10-25-2017 18:22
Found In Egroup: Facility Control
\ view thread
Can a GPI trigger be used to trigger a buttons on another computer running DashBoard. Example one Buttom on one computer will also trigger another button on another computer.
Posted By Robert Pralle 01-18-2017 14:27
Found In Egroup: Facility Control
\ view thread
Where do you find ogScript "Script Pallet" . #DashBoard
Posted By Robert Pralle 11-15-2016 15:56
Found In Egroup: Facility Control
\ view thread
Having problem with this script. var oldValue = ogscript.getObject('0x10CD-Old'); var xpt = params.getValue(0x10CD,0); if (oldValue == xpt) return; ogscript.putObject('0x10CD-Old', xpt); if (xpt == 1005) rosstalk.sendMessage('172.16.0.102', 7788, 'MEM 01'); rosstalk.sendMessage('172.16.0.103', ...
Posted By Robert Pralle 03-23-2016 14:52
Found In Egroup: Production Switchers
\ view thread
Here is an example of what you asked. It changes color of the TEST button when you turn on MLE-1 KEY-1 on or off. You can substitute the if and eles statement for anything you want. Note just chang the IP add. to your switcher's add. var oldValue = ogscript.getObject('0x992-Old'); ...
Posted By Robert Pralle 03-21-2016 15:49
Found In Egroup: Production Switchers
\ view thread
Yes you can do this in Dashboard. #Carbonite
Posted By Robert Pralle 01-19-2016 18:28
Found In Egroup: Facility Control
\ view thread
I have a NK-3G34 Video RTR. I made a Macro button to set the RTR. It will work one time only. If the Router resets it will work again but only one time. It has in the past been fine. I have not had to use it for a while. It has been working and I have not made any changes to Dashboard. Below is script ...
Posted By Robert Pralle 12-27-2015 12:24
Found In Egroup: Production Switchers
\ view thread
I was off last week. If you want I can send you one of my spare AJA converters for testing. As I said I am going Component to SDI. Let me know if that will help. #Carbonite
Posted By Robert Pralle 12-20-2015 12:26
Found In Egroup: Production Switchers
\ view thread
I AM IN STANDARD MODE 6 FSFC WHY DOES VERSION 11.01 WORK AND 11.1 DOES NOT? #Carbonite
Posted By Robert Pralle 12-18-2015 15:31
Found In Egroup: Production Switchers
\ view thread
Another not I also tried two different AJA converters. Same findings #Carbonite
Posted By Robert Pralle 12-18-2015 15:30
Found In Egroup: Production Switchers
\ view thread
I have a Carbonite 1ME. I made a test to see if I was doing something wrong. I used a Panasonic DVC Prow for the test. The DVC Pro was not gen locket to my system. I used the SD SDI output and the Y- R-Y B-Y outputs into the AJA Analog to digital converter. Fed both inputs one at a time into the same ...
Posted By Robert Pralle 12-17-2015 20:31
Found In Egroup: Production Switchers
\ view thread
The frame syncs are on. The format is 1080i/59.94 version 11.1 does not work when I use version 11.01 it does. #Carbonite
Posted By Robert Pralle 12-17-2015 19:08
Found In Egroup: Production Switchers
\ view thread
I was trying to frame sync a 480I video non synced signal in to my switcher using an AJA D10AD Analog to SDI converter. Using software version 11.1 I do not seem to get a lock and the picture is running up and to the left on the screen. Using software version 11.01 all works fine. Is there a difference ...
Posted By Robert Pralle 10-15-2015 18:47
Found In Egroup: Production Switchers
\ view thread
I NEED GLASSES. I DID NOT SEE THE MISSING (. AND 0) FRO VER 11.0.1 TO 11.1. I WILL UPGRADE. THANKS. #Carbonite
Posted By Robert Pralle 10-15-2015 16:20
Found In Egroup: Production Switchers
\ view thread
I see standard mode is being replaced with a new FSFC Mode that will also include MiniMEs. It looks like in this mode you will have 4 FSFC, 4 DVE and now adds 4 MiniME. I tired to get into this mode but I must be missing somethig. Pleas advise how to get into this mode.
Posted By Robert Pralle 09-17-2015 14:47
Found In Egroup: Production Switchers
\ view thread
I have been going over ver-11 many nice changes. I like the fact that you now can see what memories are being used. The problem is I do not see any way like in custom control to delete a memory so you can see it is empty and reuse it. Also is there any way to name the memories like custom controls? ...
Posted By Robert Pralle 09-02-2015 14:43
Found In Egroup: Facility Control
\ view thread
Any way for DashBoard to talk to my NK Router and Call up Macros from the RCP-NK1 Panel.
Posted By Robert Pralle 08-14-2015 13:20
Found In Egroup: Facility Control
\ view thread
Yes this can be done. I have made many panels and have not had any problems separating the buttons. It might be better to talk to you about this. You can E:Mail me at rjpralle@mbcocala.org. I will send you some pix of panels I have made. Robert #DashBoard