Posted By Ian Yeh 02-13-2019 19:23
Found In Egroup: Production Workflow
\ view thread
Hi Snowhockey, I'm assuming the custom controls included the proper amount of pauses, one for running the animation to cover the screen enough to do your under cut, and one to run the rest of the animation? Have you reloaded the custom controls after this was created? Go Rundown Control, Tools, ...
Posted By Ian Yeh 02-22-2018 11:40
Found In Egroup: Production Workflow
\ view thread
Last week we got upgraded to Vision Switcher 17.3h and Overdrive 12.0.13. Now if we double tap to fast (as fast as we did before the upgrade) into double graphics and a shot we get the following error "Could not perform transition because Device Transitions may only be used when a MOS Device ...
Posted By Ian Yeh 01-19-2018 18:41
Found In Egroup: Production Workflow
\ view thread
You can leverage one of the two clean feeds of each MLE, and place your server channel on the BKGD bus, and assign the TONS device in the BKGD bus in your OD template. Then, to cover up the server channel, layer your keyers. #OverDrive
Posted By Ian Yeh 01-19-2018 17:35
Found In Egroup: Production Workflow
\ view thread
Hi, what Ross switcher do you have? Vision or Acuity? In order to have a server channel auto-roll, it must be tallied, which means you have to put the server channel on the BKGD or a Keyer. #OverDrive
Posted By Ian Yeh 04-15-2015 15:30
Found In Egroup: Production Workflow
\ view thread
Hi Amy, When you were recording the relative custom control to trigger the "Auto Trans" button to run your sequence, did you have any re-entries taking place on the switcher? (MLE 1 or MLE 2 selected on the program MLE, or other MLEs selected in other MLEs) Make sur ethat you don't have any re-entry ...
Posted By Ian Yeh 03-11-2015 17:39
Found In Egroup: Production Workflow
\ view thread
That's correct. #OverDrive
Posted By Ian Yeh 03-08-2015 22:21
Found In Egroup: Production Workflow
\ view thread
Hell Steve, You are right, in that a GPI connected between the Synergy to OverDrive server is the only way to trigger OverDrive to "take and prepare next" when you run an interstitial transition on the Synergy switcher. #OverDrive
Posted By Ian Yeh 03-31-2014 17:30
Found In Egroup: Production Workflow
\ view thread
Hi Favian, Is your video server set up to delay a few frames in the switcher? We often do this to pre-roll the server to avoid the on-air pause when you take the video. If a pre-roll is set, then the switcher will delay taking the server to air (either cutting it on to program, or as a key), depending ...
Posted By Ian Yeh 02-21-2014 01:58
Found In Egroup: Production Workflow
\ view thread
Amy, In the Personality menu, when you have "OverDrive" selected, the options below should gray out (as in lock out mode), and when you dial away from OverDrive, the options should reappear. Did you turn off Editor Enabled? (Home/More/Remote Enables/Editor set to "off") #OverDrive
Posted By Ian Yeh 01-24-2014 00:10
Found In Egroup: Production Workflow
\ view thread
Thanks for checking on that. Can you tell us what version Overdrive you're using? Also the software version for the Vision switcher? To find out, go to the Help menu on Rundown Control, and select "About." You should see the software version as well as the build number. On the switcher, simply ...
Posted By Ian Yeh 01-23-2014 23:01
Found In Egroup: Production Workflow
\ view thread
Hi Amy, Just wondering if the Viz 3 is set to " Force Cue to PGM?" You can check this by going to the Template Editor and look at the device "Viz 3." It should be set to "Force Cue to PST." If it's set to "Force Cue to PGM," as soon as you take the QR template to take Viz 3 on air, it cues ...
Posted By Ian Yeh 11-14-2013 19:39
Found In Egroup: Production Workflow
\ view thread
Hi John, Jason is absolutely correct. The easiest (and cleanest) approach to do this would be to have four DVEs per MLE, or have a 4MLE switcher, so that you can create templates using two MLEs. Can you do a triple box by utilizing the DVEs in MLE 3, and add to the two boxes you already ...
Posted By Ian Yeh 11-08-2013 18:39
Found In Egroup: Production Workflow
\ view thread
Hi Adam, When you try to cue the clip(s) in question, do you see a pop up dialogue on the switcher's touchscreen that says "Clip ID Not Found?" The yellow triangle, depending on what message it's giving you, indicate either a missing clip, or an invalid clip. Missing clip suggests that ...
Posted By Ian Yeh 08-10-2013 02:11
Found In Egroup: Production Workflow
\ view thread
You're welcome. I should add that to switch between transitions (dissolves, DVE wipes, etc.), build some relative customs that record the necessary keystrokes to call up a transition, and you'll be able to toggle between them. Again, I would probably dedicate a tab of QR customs for these, so you have ...
Posted By Ian Yeh 08-09-2013 19:11
Found In Egroup: Production Workflow
\ view thread
Hi Favian, You can do this by using the switcher's clean feed, and the clean feed will be sent to the monitors. To set up the clean feed on the switcher, go to Home/More/Setup/Installation/Outputs/Clean Feed. On the right side of the menu, dial to MLE 1, second knob to Clean Feed 1 and select ...
Posted By Ian Yeh 06-04-2013 01:49
Found In Egroup: Production Workflow
\ view thread
Hi Jason, First of all, I apologize for the late reply. I was the trainer at your station, KSWB, and if I recall correctly, your station has a 4MLE Vision switcher. When you build a two-MLE effect, you are building it so that when OverDrive recalls the effect in the template, it either ...
Posted By Ian Yeh 08-21-2012 22:11
Found In Egroup: Production Workflow
\ view thread
Hi John, Normally a restart of the switcher frame and panel, server, and client will do. This should be done at least once a week, and you should create a backup file once a week. To create a backup file, launch Rapid Restore, and follow the steps to create the file. I usually save it on ...
Posted By Ian Yeh 06-21-2012 19:42
Found In Egroup: Production Switchers
\ view thread
On the switcher's touchscreen, go to home/more/setup/personality. Scroll to "Re-entry Loop" and turn it on. This will allow you to take the clean feed as a source. #Vision
Posted By Ian Yeh 06-21-2012 18:13
Found In Egroup: Production Switchers
\ view thread
Hey John, For this effect, you will utilize the clean feed as well. Assuming you already have your clean feeds set up for MLE 1 and 2. First build your chroma key effect on key 1. Then in key 2, use auto select key and key your double box background. In key 3 you will build your 2 channel DVEs ...
Posted By Ian Yeh 06-21-2012 12:57
Found In Egroup: Production Workflow
\ view thread
Hi John, You are at WHSV in Harrisonburg, VA correct? If so I was your trainer and I believe I gave you the instructions on setting this up. Are you using this template back-to-back? If you are, then what you're seeing is normal. The custom control will trigger when the memory is recalled on the ...