Posted By Gary Cook 07-09-2015 13:05
Found In Egroup: Facility Control
\ view thread
Hi Shane, Carbonite will accept either MEAUTO or MLEAUTO, they will do the same thing. There is a newer version of Carbonite available (10.1.0), although these functions should work fine in the version you have. When creating the RossTalk task in Dashboard I suggest you choose "Custom" and then ...
Posted By Gary Cook 02-05-2014 18:22
Found In Egroup: Production Switchers
\ view thread
Hi Robert, The substitution table is only used for Multiscreen shows where MiniMes are put together to make a single screen. When running in this mode, the default behavior for background sources is to zoom in on the sources so they fill all screens. If however you have a device that produces ...
Posted By Gary Cook 02-05-2014 18:16
Found In Egroup: Production Switchers
\ view thread
Robert, The manual updates are coming soon. In the meantime, all of the RossTalk commands should work with MiniMEs. Instead of using MLE(or ME), you can use MME to refer to the miniMEs. For example: MLECUT MME:1 let me know if you need anything else, Gary #Carbonite
Posted By Gary Cook 09-26-2012 20:57
Found In Egroup: Production Switchers
\ view thread
The reason why you get a black box is because the chromakey not only creates an alpha signal from the green content, but it also removes green content from the video signal (replacing it with black). So when the mask is forced you get black. One solution is to use another key on top. Use ...
Posted By Gary Cook 08-24-2012 20:22
Found In Egroup: Production Switchers
\ view thread
The set commands will return a success (0180) or failure (85) based on the validity of the GVG100 command. But that doesn't indicate whether or not the command was successful. For example setting PGM to input 99 is a valid GVG 100 command, but the switcher can't do it. In this case the return ...
Posted By Gary Cook 08-23-2012 21:39
Found In Egroup: Production Switchers
\ view thread
Hi David, the injectGVG100command function returns the value, but doesn't print it to the screen. To show the return code try this: print(injectGVG100command("020041")) Gary #CrossOver