Profile

Stefan Schindler

Contact Details

My Content

1 to 20 of 36 total
Posted By Stefan Schindler 06-26-2015 17:24
Found In Egroup: Graphics
\ view thread
Hey, is there any chance to run a json connection as datalinq source ? thanks for help
Posted By Stefan Schindler 06-26-2015 17:24
Found In Egroup: Graphics
\ view thread
Hey, is there any chance to run a json connection as datalinq source ? thanks for help
Posted By Stefan Schindler 06-09-2015 17:50
Found In Egroup: Production Switchers
\ view thread
Hey, is there a chance to change the settings of gpi in 2 in a macro ? i like to make shure my guys running a foot control not run gpi 2 by accident - only when i want it maybe its a feature request for the future
Posted By Stefan Schindler 03-18-2015 13:48
Found In Egroup: Production Switchers
\ view thread
Hey, is there a chance to create a Macro that stops all running macros ? i have sometimes a situation that i'm stuck or need to stop the next step of the macro running thanks for the help
Posted By Stefan Schindler 02-20-2015 16:57
Found In Egroup: Facility Control
\ view thread
Hey Greg, its on the Switcher - could be any other input button. The LCD ist the one on the top with the 3 push buttons under it. my only wish is to put an on / off command in my macro to change the mic state on the mixer. #DashBoard
Posted By Stefan Schindler 02-20-2015 16:35
Found In Egroup: Facility Control
\ view thread
the way i do it is i set up a a device to like button 13 on the panel and everytime i push it i get the device details in the lcd . i push next next to get the gpi trigger windows - once i click gpi 1 then it should do something - i want to save that then to the macro. if you have a better way ...
Posted By Stefan Schindler 02-20-2015 14:30
Found In Egroup: Facility Control
\ view thread
https://gist.github.com/anonymous/87adad9e984d09188d82#file-stereo there we go - its button 1 on the stereoscore test file. just set to gpi 1 and your code is inserted. not shure if i did that correct. #DashBoard
Posted By Stefan Schindler 02-19-2015 21:24
Found In Egroup: Facility Control
\ view thread
hm its not working : 0x20 is channel 1 or 0 on the setup 0x21 is another channel - its channel 2 then. on button press its LEVELSET CHON channel=0, value=0 and on another press its LEVELSET CHON channel=0, value=1 #DashBoard
Posted By Stefan Schindler 02-19-2015 20:41
Found In Egroup: Facility Control
\ view thread
Nope its not working :( i have to admit i have almost zero skills in that :( #DashBoard
Posted By Stefan Schindler 02-19-2015 20:08
Found In Egroup: Facility Control
\ view thread
i see the problem - if it take the sample for the 01v96 it works with the gpi command. the problem is that the command gpi sends always is the same command set by the sample buttom it sends : LEVELSET CHON channel=1, value=0 when the is also set to off - so it sends 0 to the 0 status ...
Posted By Stefan Schindler 02-19-2015 19:08
Found In Egroup: Facility Control
\ view thread
yeah i thought that. i tooked a cut buttom from the other dashboards and set that one up to cut on my carbonite. i then set the gpi 1 command on the button properties. ips and ports are checked it doesnt take my gpi 1 command coming from the carbonite send though rosstalk :( if i ...
Posted By Stefan Schindler 02-19-2015 18:02
Found In Egroup: Facility Control
\ view thread
Hey, i trying to push a button on the Dashboard though a GPI Trigger fired by the Carbonite. I`m using the 01v96 Sample to put Button on / off commands - the connection works an i can make my audio channel on or off. what i want is to trigger that though the Carbonite GPI command ...
Posted By Stefan Schindler 02-12-2015 03:16
Found In Egroup: Production Switchers
\ view thread
nope thsts the problem. i will reimage the carbonite.again #Carbonite
Posted By Stefan Schindler 02-11-2015 21:53
Found In Egroup: Production Switchers
\ view thread
i cant be. i have 2 different pcs - both of them show the same problem. switcher is rebooted 2 times already. #Carbonite
Posted By Stefan Schindler 02-11-2015 21:07
Found In Egroup: Production Switchers
\ view thread
the same. it opens up the url but you only see ross on the top and thats it. the m1 m2 m3 m4 buttons and all the others things are not there. just empty window #Carbonite
Posted By Stefan Schindler 02-11-2015 19:58
Found In Egroup: Production Switchers
\ view thread
hey. got the same problem. system was rebooted before and i even tryed a fresh formated stick. got no window on dashboard webbrowser chrome / iexplore it was working before i restarted the system #Carbonite
Posted By Stefan Schindler 02-05-2015 16:22
Found In Egroup: Facility Control
\ view thread
found it thanks - will try your code then. #DashBoard
Posted By Stefan Schindler 02-05-2015 15:34
Found In Egroup: Facility Control
\ view thread
ok what i did was . rosstalk.sendMessage('10.32.16.81', 9990, ' VIDEO OUTPUT ROUTING:') rosstalk.sendMessage('10.32.16.81', 9990, ' 1 0') rosstalk.sendMessage('10.32.16.81', 9990, '') 1 0 is for input output how to i trigger that button from the carbonite #Das ...
Posted By Stefan Schindler 02-05-2015 09:42
Found In Egroup: Facility Control
\ view thread
Hey, i`m looking for a way to send telnet commands to an blackmagic videohub trough the dashboard or via carbonite panel. any samples flying around ?
Posted By Stefan Schindler 02-04-2015 08:20
Found In Egroup: Production Switchers
\ view thread
works without problems - just add the 3play to devices. thank you #Carbonite