Profile

Joe Carter

Contact Details

My Content

1 to 2 of 2 total
Posted By Joe Carter 08-08-2016 14:21
Found In Egroup: Video Servers & Replay Systems​
\ view thread
Just wanting to chime in on a similar issue I've encountered with Dashboard not communicating properly with Blackstorm... The cause was due to a Group Policy setting that identified the private control room network as 'Public', therefore limiting lots of port communication despite explicit firewall rules. ...
Posted By Joe Carter 09-18-2014 22:30
Found In Egroup: Production Switchers
\ view thread
Although the original post was two years ago, I wanted to share my recent solution to this very same problem I had getting our Ki Pro Rack to fire off. I used an Arduino with an Ethernet shield to accept a GPO from the switcher, it then sent a HTTP GET to the Ki Pro with the query string for the play ...