Profile

David Russell

Contact Details

My Content

1 to 3 of 3 total
Posted By David Russell 12-22-2025 08:08
Found In Egroup: Connectivity
\ view thread
Hi Robert, In the tally console software, the source definition table is not updated dynamically - the names in the first column do not update if the name in the upstream router changes. You can however set the router to be the default source of names If you navigate to Hardware > Com Ports > Routers ...
Posted By David Russell 11-17-2025 10:58
Found In Egroup: Connectivity
\ view thread
Hello Boris, Ultriscape has two different styles of UMD objects The standard UMD object which is associated with a video PIP - these are driven via TSL protocol messages. The 2nd type is the Remote RossTalk driven label object I am not aware of a way to send TSL based messages from the switcher ...
Posted By David Russell 11-17-2025 10:58
Found In Egroup: Connectivity
\ view thread
Hello Boris, The Ultriscape UMD's use TSL protocol based messages to send tally state to a UMD object. I do not know of a way to send TSL based messages from an Acuity SDPE based on a GPI input triggers. You could create a custom control on the switcher that would send a RossTalk label message ...