Posted By Mark Macklin 06-19-2025 09:58
Found In Egroup: Facility Control
\ view thread
Hi Andreanne, Is it possible to identify which video server is on air or in preview? And is there any more information that can be retrieved with the listener? For instance if I wanted to know what was coded in a shot could I display that as well? Thanks! ------------------------------ Mark ...
Posted By Mark Macklin 11-28-2024 10:19
Found In Egroup: Facility Control
\ view thread
Hey Nathaniel, stacking order matters for being able to tab between items. So if you want to tab between item 1 and 2 you'll want them back to back in the running order of the panel. ------------------------------ Mark Macklin ------------------------------
Posted By Mark Macklin 10-27-2023 11:29
Found In Egroup: Facility Control
\ view thread
This is very helpful! My question is there a way to have a consumer panel have it pull / populate the OID information? It works fine once I start populating / changing OIDs when the panels are active but doesn't on launch pull in that information. ------------------------------ Mark Macklin ...
Posted By Mark Macklin 10-25-2023 12:29
Found In Egroup: Facility Control
\ view thread
Opening up an oldie, I was looking into interlinking panels and wanted to reference the post at the top of this https://discussions.rossvideo.com/forum/default-forum-gc1/dashboard-gc43/12006-multiple-dashboards But that doesn't seem to exist anymore. Any chance of getting this original post ...
Posted By Mark Macklin 06-01-2023 15:56
Found In Egroup: Facility Control
\ view thread
Hey Kurt! That is very helpful to know, thanks for the update. remembering to put the return in properly gets me each time. ------------------------------ Mark Macklin ------------------------------
Posted By Mark Macklin 11-18-2022 16:49
Found In Egroup: Facility Control
\ view thread
How dare you James haha, your brain scares me but I am glad you are there to know the answers to my random questions. Truly appreciate all the help you provide! ------------------------------ Mark Macklin ------------------------------
Posted By Mark Macklin 11-16-2022 16:07
Found In Egroup: Facility Control
\ view thread
On Dashboard you'll need to enable the listener under preferences: And then on the item you are trying to control add in a trigger ID: And from Streamdeck the command is GPI (Trigger ID) so if the trigger ID was TEST the command would be GPI TEST ------------------------------ ...
Posted By Mark Macklin 11-16-2022 15:56
Found In Egroup: Facility Control
\ view thread
I tried this James but no luck, read timed out is what ends up happening. ------------------------------ Mark Macklin ------------------------------
Posted By Mark Macklin 09-28-2022 20:09
Found In Egroup: Facility Control
\ view thread
I am trying to ask the Acuity what the state of a key is via Dashboard, but I don't get a result back. I know how to query when doing something like XPT MLE:6:KEY:1:? but not for something like KEYSTATE 6:1. Guessing I am just missing something simple. Here is what I was trying: function callb ...
Posted By Mark Macklin 09-05-2022 13:55
Found In Egroup: Production Switchers
\ view thread
I have a split key and was wondering what the syntax was to change channel 2 on the key via RossTalk? Couldn't seem to find anything that worked. Base command is normally - XPT ME:1:KEY:1:IN:111 Is there a way to tell it that channel 2 of key 1 should be changing instead of channel 1? Thanks ...
Posted By Mark Macklin 03-18-2022 15:50
Found In Egroup: Facility Control
\ view thread
Is there a way to enable listen for incoming GPI trigger commands like there is on Dashboard? I am currently setup to send to the Ultritouch on port 7788 but the GPI trigger is not being fired. Thanks. ------------------------------ Mark Macklin ------------------------------
Posted By Mark Macklin 02-04-2022 14:14
Found In Egroup: Facility Control
\ view thread
Don't know if there is or not, what I did was create a button that put you into "cleaning mode" it set a parameter to 0 popped a new canvas with one small button on it. Each time the button is hit it would check the parameter and if it was less than 5 it would add 1 to the parameter, once it was 5 it ...
Posted By Mark Macklin 02-04-2022 14:08
Found In Egroup: Facility Control
\ view thread
You'll need to open a port on the Vision switcher in the Communication Settings. You'll want to use RossTalk IN or RTalkIN (forget how it is labeled) usually 778 is used as the default. ------------------------------ Mark Macklin ------------------------------
Posted By Mark Macklin 11-22-2021 15:26
Found In Egroup: Facility Control
\ view thread
Is it possible to send commands to increase and lower the brightness of the Ultritouch panel? I know you can go into the menu and manually do it but I was hoping for the option to just send a command to do it. Thanks. ------------------------------ Mark Macklin ------------------------------
Posted By Mark Macklin 08-20-2021 16:51
Found In Egroup: Facility Control
\ view thread
Hi Anand, Thank you all very much! Working perfectly now, sorry for the trouble, greatly appreciate all the effort. ------------------------------ Mark Macklin ------------------------------
Posted By Mark Macklin 08-18-2021 14:00
Found In Egroup: Facility Control
\ view thread
Hey Anand, \n still gets read timed out. Putty gets the response like Les indicated it should. Just so you know I do query the switcher regularly for XPT information, but like you indicated that statement ends in a ? and just uses the sendMessage. Thanks for all the effort you are putting into ...
Posted By Mark Macklin 08-17-2021 16:51
Found In Egroup: Facility Control
\ view thread
No worries, appreciate the replies to begin with! So the exception went away and instead I am getting read timed out instead. Replaced with commands I know work without the sendMessageWithResponse and still get the read timed out. Did I need to add something to the (success, cmd, result, exception) ...
Posted By Mark Macklin 08-10-2021 14:44
Found In Egroup: Facility Control
\ view thread
If you use \n in the name it will force a line break. Example name: BANANA PHONE -> Change to BANANA \nPHONE That will change it to: BANANA PHONE ------------------------------ Mark Macklin ------------------------------
Posted By Mark Macklin 08-09-2021 13:39
Found In Egroup: Facility Control
\ view thread
I tried this: rosstalk.sendMessageWithResponse(%const['hosts']['ACUITY.host']%, %const['hosts']['ACUITY.port']%, 'MEM ?:2', callbackFunction); But that made Dashboard unhappy and it threw an exception. And I can't really push for an upgrade since this is just me playing with something on the side. ...
Posted By Mark Macklin 08-06-2021 14:11
Found In Egroup: Facility Control
\ view thread
Well I gave it another go with no success, tried out most of the other commands and got results just nothing for the memory query. Script as follows: function callbackFunction(success, cmd, result, exception) ( ogscript.debug(result); ) rosstalk.sendMessage(%const['hosts']['ACUITY.host']%, %c ...