Posted By Sylvain Levacher 08-31-2023 05:36
Found In Egroup: Production Switchers
\ view thread
Thank you less for your reply, it's the Next button that was missing in my setup procedure. I was able to set the IP address and port value. Everything is working properly now. Sylvain ------------------------------ Sylvain Levacher Technical manager OPERA NATIONAL DE PARIS --------- ...
Posted By Sylvain Levacher 08-30-2023 09:13
Found In Egroup: Production Switchers
\ view thread
Hello, After a reset, my Carbonite black switcher lost the configuration used to communicate the TALLYs with the Ultrix. This switcher has been upgraded to version 15.6.1.19113. I can no longer find the menus used to configure the TSL_UMD protocol, which is used to communicate tally status to the ...
Posted By Sylvain Levacher 10-01-2021 09:15
Found In Egroup: Production Switchers
\ view thread
Hi Les, indeed the problem came from a wiring error. thank you for your help Sylvain ------------------------------ Sylvain Levacher Technical manager OPERA NATIONAL DE PARIS ------------------------------
Posted By Sylvain Levacher 09-20-2021 03:40
Found In Egroup: Production Switchers
\ view thread
Hello evryone, I have LTC timecode connected to the Carbonite Black switcher on dedicated LTC port, but the switcher is not showing it, it seems to be receiving nothing. The status page indicates "n / a" in the Status column. Is there something to do in order for it to be operational in Carbonite black? ...