Posted By Tomer Bron 10-08-2023 18:16
Found In Egroup: Production Switchers
\ view thread
Hi Les, First - I really appreciate all the help, I was able to install the dashboard and I can see it's running version 13.0.4.17417, I enabled the Editor as you suggested and it worked perfectly, My goal is to control the carbonite switcher with the following commands: Set program/preset ...
Posted By Tomer Bron 10-06-2023 08:14
Found In Egroup: Production Switchers
\ view thread
Hi Les, There might have been a monitor a while back, but it's an old switcher that had moved between many control rooms, its possible it has disappeared at one of the packing/unpacking, none of the current staff could say if there was a screen in the past, Is that a software I could ...
Posted By Tomer Bron 10-05-2023 12:39
Found In Library: Production Switchers
Posted By Tomer Bron 10-05-2023 12:39
Found In Egroup: Production Switchers
\ view thread
That sounds about right, (image attached, don't know if it'll mean much) Alternatively, I've started exploring the gvg100 protocol, I get "editor functionality is not enabled" on every command I send, Is there a way to enable it? ------------------------------ Tomer Bron ...
Posted By Tomer Bron 10-05-2023 12:27
Found In Egroup: Production Switchers
\ view thread
that is a good question, I think it's kind of old (very old) machine, it has no external mounted screen (perhaps it was removed..) it has a 2 line small screen that says on the top right v1.306, does that make any sense? ------------------------------ Tomer Bron Developer ...
Posted By Tomer Bron 10-05-2023 12:14
Found In Egroup: Production Switchers
\ view thread
Hi Les, On another issue - I would like to use RossTalk to turn on a key on our carbonite switcher, I've followed https://help.rossvideo.com/carbonite-device/Topics/Protocol/RossTalk/CNT/RT-CNT-Comm.html "KEYCUT 2:4" toggles the key4 state on me2, works perfectly! however "KEYCUTON ...
Posted By Tomer Bron 07-13-2023 16:48
Found In Egroup: Production Switchers
\ view thread
Hi James, thanks for the reply! so what would be the right way to query the switcher for current crosspoint selection? ------------------------------ Tomer Bron Developer ------------------------------
Posted By Tomer Bron 06-17-2023 15:56
Found In Egroup: Production Switchers
\ view thread
Hi all, I'm trying to connect and send RossTalk commands to our carbonite switcher, Sending the commands seems to be working great! however - I'm not getting any feedback, for example after triggering auto trans on an ME, I'm not getting any notifications that the A and B bus have changed crosspoints, ...