Posted By Kurt Stoneburner 11-14-2023 22:58
Found In Egroup: Production Workflow
\ view thread
I'm looking to solve a variation on this theme. Is there a way to change the output Framebuffer programatically? We have several XPression templates where we would like to output to a different Framebuffer based on the value of a user selected dropdown box. It's easy enough to test the ...
Posted By Kurt Stoneburner 08-02-2023 01:04
Found In Egroup: Production Switchers
\ view thread
Thank you Louis and Les. I took both of your advice. I ended up using two Caprica systems to talk to a single device using RossTalk. For safety, I enabled the device, sent the message, then disabled the device. Enabling the RossTalk device added 20 frames of delay which was acceptable for this project. ...
Posted By Kurt Stoneburner 07-31-2023 14:48
Found In Egroup: Facility Control
\ view thread
I have two Acuities in separate control room that need to send RossTalk commands to the same device. The listening device can only listen on a single port. Does Acuity RossTalk establish a continuous connection to an IP:Port? Or does it connect, send a command, then disconnect? If it's the ...
Posted By Kurt Stoneburner 07-31-2023 14:48
Found In Egroup: Production Switchers
\ view thread
I have two Acuities in separate control room that need to send RossTalk commands to the same device. The listening device can only listen on a single port. Does Acuity RossTalk establish a continuous connection to an IP:Port? Or does it connect, send a command, then disconnect? If it's the ...
Posted By Kurt Stoneburner 06-01-2023 00:57
Found In Egroup: Facility Control
\ view thread
I found another solution with Dashboard 9.2: Using sendMessage with: mem ?:2:? Adding the additonal question mark seemed to make the RossTalk work. Sample Code: rosstalk.sendMessage(acuity_ip, acuity_port), 'mem ?:2:?', function(success, cmd, result, exception)( //*** Display ...
Posted By Kurt Stoneburner 06-01-2023 00:23
Found In Egroup: Production Switchers
\ view thread
Bryan, You can assign a Background Generator as an input source using Bus Maps. Navigate to: Setup --> Installation --> Bus Maps Assign an input to a Background Generator. BKGD 1 & BKGD 2 should be the first two listed sources. ------------------------------ Kurt Blank ABC ...