Posted By Les O'Reilly 07-27-2026 16:25
Found In Egroup: Production Switchers
\ view thread
What would be better is to setup a Carbonite Sim and then you will be able to have a fully functioning offline tool. Then once you go to connect you just change the Data source to point to the newly active real switcher frame. https://rossvideo.community/viewdocument/carbonite-ultrasim-v94 --- ...
Posted By Les O'Reilly 07-23-2026 09:54
Found In Egroup: Production Switchers
\ view thread
https://support.rossvideo.com/hc/en-us Please follow the link above and open a ticket with support so they can assist you. ------------------------------ Les O'Reilly Director, Switcher Product Management ------------------------------
Posted By Les O'Reilly 07-23-2026 09:54
Found In Egroup: Infrastructure​
\ view thread
https://support.rossvideo.com/hc/en-us I would recommend opening a ticket with Support. ------------------------------ Les O'Reilly Director, Switcher Product Management ------------------------------
Posted By Les O'Reilly 07-23-2026 09:52
Found In Egroup: Facility Control
\ view thread
The Global listener only Parses on the GPI command. GPI is "General Purpose Interface" and was common on many devices (and kind of still is the basics if you do arduino / ESP32 projects as well) When the RossTalk protocol was made with lots of commands -- the GPI command simulated this ability to just ...
Posted By Les O'Reilly 07-21-2026 12:11
Found In Egroup: Production Switchers
\ view thread
No that is not possible. You are forcing that name by selecting the TSL UMD ID and setting it to use the Name. That is what is telling the switcher to use that name on the panel. We can Add this to Feature Requests List ------------------------------ Les O'Reilly Director, Switcher Product Management ...
Posted By Les O'Reilly 07-17-2026 12:58
Found In Egroup: Production Switchers
\ view thread
I am not suggesting it is wrong to do it the way you did -- it's infact a way to ensure that "multiple" things don't run from the Global. Running a local listener allows you to create a different port and "connection" for each panel. The Global Listener is just there for convenience and will pass GPI ...
Posted By Les O'Reilly 07-17-2026 10:42
Found In Egroup: Production Switchers
\ view thread
Example as I guess if I keep the capture small it looks okay... I have rosstalk sending out GPI PGMME1 as the value from that button. And the one bellow now has that as the trigger id and they work. For sure the issue with the value is not DashBoards limit to a character set. And the internal listeners ...
Posted By Les O'Reilly 07-17-2026 10:36
Found In Egroup: Production Switchers
\ view thread
Hopefully that stay readable -- I made two buttons to send two different CCs to my switcher I then gave them GPI 1001 and GPI 1002 I then Made two Buttons above that send RossTalk to the Global listener that I setup on 7791 and those buttons just send GPI 1001 or GPI 1002 pressing the RT buttons ...
Posted By Les O'Reilly 07-17-2026 09:23
Found In Egroup: Production Switchers
\ view thread
I will next time I guess just put it in a Word doc and post that ... I did not realize that the posts were compressing the images and that you could not click on them to make them bigger. FYI - you are doing something different then what I last posted if you needed to turn on the internal listener - ...
Posted By Les O'Reilly 07-10-2026 16:47
Found In Egroup: Production Switchers
\ view thread
Okay New plan... Let's just make it all in visual Logic and our own buttons instead of dragging the file set buttons and trying to attach to them. I have kept the entire File Set interface (but only to make it easy to find the "values" of the constraint to pass for the Set I want to get access too. ...
Posted By Les O'Reilly 07-09-2026 18:46
Found In Egroup: Production Switchers
\ view thread
okay so I figured out how to make it work. you can open the switcher Config Load Sets page in Carbonite and enable "edit mode" using CTRL+G Now in your custom panel also enable Edit Mode and then Drag the Button from Carbonite into the custom Panel: and it should look like this so make sure to include ...
Posted By Les O'Reilly 07-08-2026 11:25
Found In Egroup: Production Switchers
\ view thread
You could build something like that and send RossTalk messages -- however the issue you can't get around is that the user will still have to press the Confirmation Pop up manually. ------------------------------ Les O'Reilly Director, Switcher Product Management -------------------------- ...
Posted By Les O'Reilly 07-02-2026 10:14
Found In Egroup: Production Switchers
\ view thread
The Source on the BKGD Bus of the ME is what should be showing up on the output of the ME. There is a setting in the Config / System / Global for setting pass or Strip of Anc Data. Note any FSFC that is assigned to an input is going to Strip the ANC Data and that includes the CC. ---------- ...
Posted By Les O'Reilly 06-30-2026 16:31
Found In Egroup: Production Switchers
\ view thread
First Lets put a new Panel. Then throw down a Basic Canvas which we can then be able to associate the data to the switcher when we pull something in Now put the Buses page into Panel Builder Mode so that you can Drag from it -- make sure you click back into the Carbonite UI first Now Let's grab the ...
Posted By Les O'Reilly 06-30-2026 16:06
Found In Egroup: Production Switchers
\ view thread
Will respond in the other thread. as a first time poster you needed to be approved (spam bot stuff) ------------------------------ Les O'Reilly Director, Switcher Product Management ------------------------------
Posted By Les O'Reilly 06-30-2026 16:00
Found In Egroup: Production Switchers
\ view thread
Make 2 empty sets of Show Files then ONLY put memories in each of them. Nothing else. Only recall those via the RossTalk Command to mitigate the elements being recalled. in the Fall when version 12.2 of carbonite is out you should be able to change the templates to trigger custom controls on the ...
Posted By Les O'Reilly 06-30-2026 15:13
Found In Egroup: Production Switchers
\ view thread
Loading File Sets in the middle of the show is a "bad" approach. Loading the set like this is going to recall everything -- this can mess up personality settings and installation settings while in the middle of operation. Saying the switcher needs to act differently while keeping the automation system ...
Posted By Les O'Reilly 06-27-2026 23:56
Found In Egroup: Production Switchers
\ view thread
Bottom of the TD Panels Page on the website has the downloads for the DXF and PDF files https://www.rossvideo.com/products/production-switchers/touchdrive-control-panels/ For panels from September 2023 and onwards: https://documentation.rossvideo.com/files/Manuals/Production%20Switchers/Touch ...
Posted By Les O'Reilly 06-25-2026 09:26
Found In Egroup: Production Switchers
\ view thread
If you use an Aux Bus (delegating the Row from a Keyer control to aux control) that should be no different between different "stripes" on the panel. Do you have pictures or a video you can share of delegating the two panel rows to the same aux and then showing them switching okay on the one panel row ...
Posted By Les O'Reilly 06-24-2026 18:34
Found In Egroup: Production Switchers
\ view thread
https://support.rossvideo.com/hc/en-us Please contact support -- it is 24 x7 and is available to all Ross Products. Someone will help get you back up. ------------------------------ Les O'Reilly Director, Switcher Product Management ------------------------------