Posted By Les O'Reilly 05-12-2026 13:35
Found In Egroup: Production Switchers
\ view thread
You are probably using the Same CK Resource in both of those. The ME keyers do not directly take control of the CK engines -- They are able to re-use the same ones so you could have the same chromakeys but then different compositions. The CK is effectively providing an Video + Alpha to the ME keyer ...
Posted By Les O'Reilly 05-06-2026 18:09
Found In Egroup: Production Switchers
\ view thread
I answered in the other post -- sorry for the delay but first time posters get held for approval to sort out the Bots/Spammers.. ME P/P is a Program / Present ME. The Ultra Family and newer lines use that concept vs the older Black/Graphite series where when you added MEs the Highest ME would be the ...
Posted By Les O'Reilly 05-06-2026 18:07
Found In Egroup: Production Switchers
\ view thread
Hi David, Those are default user buttons that ship with all the panels. ME P/P is a concept that is in the Ultra Series that was never in the Graphite however you can print labels to replace those on transparent sheets. All user button assignments can be found in the Personality Page of dashboard. ...
Posted By Les O'Reilly 05-06-2026 18:04
Found In Egroup: General Discussion
\ view thread
HI, The file does not need to be edited "in the file". When the layout is applied to the controller you then have that device in your DashBoard NODEs and you will link from it to which OIDs you need to control from which Midi Commands. You don't need to edit the file you edit the device. The custom ...
Posted By Les O'Reilly 05-04-2026 18:40
Found In Egroup: Production Switchers
\ view thread
Anciliary Data source is from the BKGD bus of the ME. ------------------------------ Les O'Reilly Director, Switcher Product Management ------------------------------
Posted By Les O'Reilly 04-25-2026 00:30
Found In Egroup: Production Switchers
\ view thread
the "CG" device type is meant for using the CII Gateway and is more for use with mos graphics where you want to control it via overdrive prior to caprica. Generally with XPression we use the RossTalk interface and you build the Custom Controls you need to control the Sequencer and take items you want ...
Posted By Les O'Reilly 04-25-2026 00:28
Found In Egroup: Production Switchers
\ view thread
in the Tally menu you can enable additional Tally calculation paths. https://help.rossvideo.com/ultrix-acuity/Tasks/Setup/Video/Input/To-Tally-Output.html Then from there you can setup on the com port sending out TSL v5 how the bits are to be used for the different Tally Paths. https://help.rossvid ...
Posted By Les O'Reilly 04-25-2026 00:21
Found In Egroup: Production Switchers
\ view thread
Set the GPO up as a Tally Mode Operation Then use an "Aux Bus" that you are not actually using as a "source" on another Aux Bus that you are not using. So lets say Aux 28 will be the fake output. You set that up as "always on air" in the on air menu. Then in the inputs you go to internal and attach ...
Posted By Les O'Reilly 04-16-2026 07:42
Found In Egroup: Production Switchers
\ view thread
Hi Rory, You might want to try to do an upgrade on the switcher and if that is not working for for a full recovery of the panel (that will require making a bootable USB and accessing the Bios to boot from that and recover the full install) https://rossvideo.community/viewdocument/touchdrive-v331-software-download ...
Posted By Les O'Reilly 04-13-2026 10:01
Found In Egroup: Production Switchers
\ view thread
You can not pass multiple events all at once in one command. It will only parse the one event. ------------------------------ Les O'Reilly Director - Switcher Product Management ------------------------------
Posted By Les O'Reilly 04-09-2026 13:31
Found In Egroup: Graphics
\ view thread
That is an issue with Companion in that it will take control of the port and "lock it up" you would be best to setup a second GPI/RossTalk board in XPression with a different port to use for Companion / Switcher etc. I can't remember if companion will allow you to change the port it uses to something ...
Posted By Les O'Reilly 04-09-2026 13:24
Found In Egroup: Production Switchers
\ view thread
No you can not export the I/O names from the list from the switcher directly. though you might be able to open the xml file that is the configuration and see if AI could parse it for you to find Inputs and outputs ------------------------------ Les O'Reilly Director - Switcher Product Management ...
Posted By Les O'Reilly 04-09-2026 13:22
Found In Announcements
HyperMax is seeing another release! In January we released version 11.1 which included the following features: Preprocessor Effects The Preprocessor creates visual effects that can be applied any 3D DVE channel. Any number of preprocessor effects can be applied to the same DVE channel. • Ultrawide ...
Posted By Les O'Reilly 04-06-2026 17:16
Found In Egroup: Production Switchers
\ view thread
When Brian Ford wrote the Memory Attributes for Vision he mentioned "we should have added a way to have Recall Overrides.." so when we were doing it for Carbonite I thought "what would Brian want to improve it...".. Great feature -- though it can at times catch people :) it is a double edge sword. ...
Posted By Les O'Reilly 04-05-2026 03:49
Found In Egroup: Production Switchers
\ view thread
This is kind of what Recall Over ride Attributes are for. Being able to set them to Forced Recall or Forced Never Recall. That can make it so that Memory recalls will not control it -- that said as well some of your other memories you are doing your Custom Control recalling memories could look to make ...
Posted By Les O'Reilly 04-02-2026 17:22
Found In Egroup: Production Switchers
\ view thread
It is not possible for the Custom Control to send those events. Those kinds of events are contained inside the panel and are not messages that are available in side of the custom control to be sent to the panel. Custom Control Events are all frame side (it's not a panel sending key stokes and button ...
Posted By Les O'Reilly 03-26-2026 22:41
Found In Egroup: Production Switchers
\ view thread
Yes what that event is doing is sending a command to the device ... it is NOT triggering a Custom Control ON your switcher. So you would use like you suggest a GPI number that is going to trigger the button on the Dashboard panel you are using as a protocol converter. RossTalk is just a TEXT String ...
Posted By Les O'Reilly 03-26-2026 19:54
Found In Egroup: Production Switchers
\ view thread
Yes but that is going to send that as the command -- that is not going to press the "switcher" custom control. you would need something on the other end that would be looking for the CC bcc command -- ie CC 104 ------------------------------ Les O'Reilly Director - Switcher Product Management -- ...
Posted By Les O'Reilly 03-26-2026 19:01
Found In Egroup: Production Switchers
\ view thread
Hi Jason, What did you setup for the command to be sent to the panel when Roll Clip is triggered? ------------------------------ Les O'Reilly Director - Switcher Product Management ------------------------------
Posted By Les O'Reilly 03-25-2026 11:55
Found In Egroup: Production Switchers
\ view thread
you won't be able to make it look exactly like a button (well I guess you could put an image behind it..) Change the widget hint to a Label. Then you can Apply Changes to see it change. now go to Style tab and you can manipulate the label to get it pretty close to what a "button" looks like. ...