Posted By Les O'Reilly 06-11-2026 11:27
Found In Egroup: Production Switchers
\ view thread
You can't run the panels off the frame. They run on the panel or on an external pc. To clarify you are good and it's working now? Plane is about to push back so won't be able to respond for some time. ------------------------------ Les O'Reilly Director, Switcher Product Management --- ...
Posted By Les O'Reilly 06-11-2026 11:22
Found In Egroup: Production Switchers
\ view thread
Please post screen shots of the device configuration for the RossTalk device setup to send to the TD panel. please also double check the IP is the panel and not the frame. in dashboard there is a debug view and yes you can attach debug messages to run after your events. ------------------------------ ...
Posted By Les O'Reilly 06-10-2026 20:48
Found In Egroup: Production Switchers
\ view thread
Do you have the Global Listener enabled in DashBoard on your panel? on the Toolbar -- Window - Preferences - RossTalk GPI Listener Enable -- also set it to 7789 and then modify your device config for sending to the panel. TD Panels may have port 7788 reserved for the Panel to run it's rosstalk listener ...
Posted By Les O'Reilly 06-10-2026 20:42
Found In Egroup: Production Switchers
\ view thread
I will answer in the other post. Because you were a first time poster you have to be approved first. It was an issue with spam. ------------------------------ Les O'Reilly Director, Switcher Product Management ------------------------------
Posted By Les O'Reilly 06-10-2026 13:05
Found In Egroup: General Discussion
\ view thread
Okay sounds like should open a ticket with support. They can probably have you run some test steps and pull logs when it passes and fails. That sounds for sure like either the GPI is not caught by the card and then sending the message to Ultrix or the ultrix is missing the message. https://support. ...
Posted By Les O'Reilly 06-09-2026 08:58
Found In Egroup: General Discussion
\ view thread
How are you trying to use the card? What help would you like with it? ------------------------------ Les O'Reilly Director, Switcher Product Management ------------------------------
Posted By Les O'Reilly 06-09-2026 08:57
Found In Egroup: Connectivity
\ view thread
The Ultrix TSL Output is for sending Labels only. This is how external Carbonite Switchers and Graphite are able to be "told" what sources are on the outputs being routed to them. There is not Tally state of the source being on air carried via that connection. If you would like to have a Tally Control ...
Posted By Les O'Reilly 06-08-2026 15:27
Found In Egroup: Production Switchers
\ view thread
Only suggestion I would make I guess would be to insert an input into the Database before Camera 1 that you can have on ID 0 that will not cause you an issue. ------------------------------ Les O'Reilly Director, Switcher Product Management ------------------------------
Posted By Les O'Reilly 06-08-2026 10:22
Found In Egroup: Production Switchers
\ view thread
The TSL UMD Protocol setup instructions are can be found here: https://help.rossvideo.com/acuity-device/Topics/Devices/UMD/TSL.html That should walk you through setting it up on the Ultrix Acuity. ------------------------------ Les O'Reilly Director, Switcher Product Management ---------------- ...
Posted By Les O'Reilly 05-28-2026 09:21
Found In Egroup: Production Switchers
\ view thread
From the other post on the same subject my reply to that was: ----------------------------- Hi David, Those are default user buttons that ship with all the panels. ME P/P is a concept that is in the Ultra Series that was never in the Graphite however you can print labels to replace those on transparent ...
Posted By Les O'Reilly 05-27-2026 10:31
Found In Egroup: Production Switchers
\ view thread
Hi Josh, Just to clear this up so no future confusion -- it is NOT ME 3 ... ME P/P is more like "ME 0" to think about it as a number. With Older Carbonite/Graphite Switchers and the Synergy/Vision/Acuity Lines the final ME always was the highest number in the system. The thing about that is when you ...
Posted By Les O'Reilly 05-27-2026 10:22
Found In Egroup: Connectivity
\ view thread
I have seen that other thread as well -- however like I wrote above we set this up while I was in singapore with the above versions and we did see that there was still a bug Yes the option for Version 5 to now have the Tally configuration is there -- but only Tally Lamps (so the Left and Right beside ...
Posted By Les O'Reilly 05-26-2026 09:13
Found In Egroup: Production Switchers
\ view thread
Without knowing how the system Tally is being wired from the switcher to the cameras it is not possible to point you to instructions. Are the tally driven by tally connections from the CCU to the Switcher tally port? Or is the system Driven by IP Tally interface? You probably will need to look at the ...
Posted By Les O'Reilly 05-22-2026 03:58
Found In Egroup: Connectivity
\ view thread
Hi Rachel, There is a setting in the the Ultriscape - Configuration - Tally Settings (top tabs second one) and the TSL 5 Tally Behaviour Settings.. That has a setting to say "only light RED when it is both.." However we were just trying it here in the Singapore office and we do have what seems to ...
Posted By Les O'Reilly 05-12-2026 13:35
Found In Egroup: Production Switchers
\ view thread
You are probably using the Same CK Resource in both of those. The ME keyers do not directly take control of the CK engines -- They are able to re-use the same ones so you could have the same chromakeys but then different compositions. The CK is effectively providing an Video + Alpha to the ME keyer ...
Posted By Les O'Reilly 05-06-2026 18:09
Found In Egroup: Production Switchers
\ view thread
I answered in the other post -- sorry for the delay but first time posters get held for approval to sort out the Bots/Spammers.. ME P/P is a Program / Present ME. The Ultra Family and newer lines use that concept vs the older Black/Graphite series where when you added MEs the Highest ME would be the ...
Posted By Les O'Reilly 05-06-2026 18:07
Found In Egroup: Production Switchers
\ view thread
Hi David, Those are default user buttons that ship with all the panels. ME P/P is a concept that is in the Ultra Series that was never in the Graphite however you can print labels to replace those on transparent sheets. All user button assignments can be found in the Personality Page of dashboard. ...
Posted By Les O'Reilly 05-06-2026 18:04
Found In Egroup: General Discussion
\ view thread
HI, The file does not need to be edited "in the file". When the layout is applied to the controller you then have that device in your DashBoard NODEs and you will link from it to which OIDs you need to control from which Midi Commands. You don't need to edit the file you edit the device. The custom ...
Posted By Les O'Reilly 05-04-2026 18:40
Found In Egroup: Production Switchers
\ view thread
Anciliary Data source is from the BKGD bus of the ME. ------------------------------ Les O'Reilly Director, Switcher Product Management ------------------------------
Posted By Les O'Reilly 04-25-2026 00:30
Found In Egroup: Production Switchers
\ view thread
the "CG" device type is meant for using the CII Gateway and is more for use with mos graphics where you want to control it via overdrive prior to caprica. Generally with XPression we use the RossTalk interface and you build the Custom Controls you need to control the Sequencer and take items you want ...